Skip to main content

SCFM Calculator

Convert actual volumetric flow to standard conditions

Instructions

1

Enter ACFM

Actual volumetric flow at operating conditions.

2

Enter Pressure (psia)

Use absolute pressure, not gauge.

3

Enter Temperature (°F)

Ambient gas temperature at the meter.

Formula

SCFM = ACFM · (P / Pₛₜd) · (Tₛₜd / T)

Pₛₜd = 14.696 psia, Tₛₜd = 60°F (520°R); T = °F + 459.67

Note: Ignores compressibility (Z ≈ 1); acceptable for low pressure gases.

About SCFM

SCFM represents volumetric flow normalized to standard conditions, enabling fair comparison between systems measured at different pressures and temperatures.

Common Questions

Is there a single standard?

Standards vary (e.g., 60°F vs 68°F). This tool uses 60°F and 14.696 psia.

What about compressibility?

For high pressure/velocity gases, include Z; we assume Z ≈ 1 here.